Form 1+
Consolidated procedure for operating the form 1+ printer
Follow this procedure for any print on this printer
1. Ready your design files in pre-form
2. Put on nitrile gloves
3. Check the resin tank for debris or damage following the instructions on the form website
4. Start your print in pre-from
5. When the print is completed, and the print bed is sitting at the top of the printer, remove the print bed and place it face up in the tray
6. Carefully remove the print with a scraper
7. Place the print in a red solo cup filled with isopropyl alcohol. Agitate the print for 5 minutes then let is sit for 20 minutes
8. Repeat step 3 to check the resin tank for damage after the print
9. Repeat step 7 with new alcohol
10. Remove the print from the alcohol and place it in the UV sterilizer for 2+ hours to harden the resin